Spring-loaded piston type assembly without reservoir. Simple design assures long troublefree service. Pin center length 7.88". Bore 5/8". Stroke 1.62". Wt. .45 oz. Ports in-line, no fittings |
Please note, Aircraft Spruce Australia's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Aircraft Spruce Australia assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.
P/N 06-01214 is a push type unit. We do not stock a pull type unit. Contact sales with the Cleveland part number and we will be happy to special order it for you.
The threads on P/N# 06-01214 are 5/16-24.
Yes, it is a TSO'd unit. The packing slip refers to it as FAA TSO'D, PMA, OR STC'D APPROVED PART.
Yes, you will need to use an external reservoir if you are using a 10-54 master cylinder.
The 10-54 has a 8" installed length and the 10-54a is shorter at 7.28". Other than that they are the same.
This does not have a mounting position spec.
Yes that is correct.