THE AVIATION SUPERSTORE FOR ALL YOUR AIRCRAFT & PILOT NEEDS | +61 (1800) 953522
Thumbs 1
Thumbs 1

Met-L-Chek Cleaner/Remover E-59A

$18.15/Each
Price Includes GST
Quantity
Add to Wishlist
Part# 09-04307
MFR Model# M-E-59A-16

Overview

E-59A is a class 2 (non-halogenated), Method C inspection penetrant remover. It is designed for use in the solvent wipe technique for penetrant inspection in general metalworking, welding, nuclear and automotive applications. It is a moderate dry rate material and is ideal for penetrant wipe removal and pre-inspection surface cleaning. As a pre-cleaner it is sprayed directly on the test surface. As a penetrant remover it is sprayed onto wiping media and then the penetrant wiped from the surface.The remover should not be sprayed directly on to the test surface to remove the excess penetrant as the sensitivity will be impaired.

E-59A is listed on the Qualified Products List for AMS-2644E. It meets the requirements of AMS-2647, ASME Boiler and Pressure Vessel Code, ASTM E-165, ASTM E-1417, and ISO- 3452-2005 for penetrant inspection materials. It is low in Sulfur, Chlorine, Fluorine and other Halogens, making it safe for use on Titanium and high Nickel alloys found in aerospace, medical and nuclear components.

E-59A contains flammable solvents and should not be used in confined spaces or near open flames or sparks.

Guide to METHOD "C" wipe off processing per ASTM E-1417-05
  1. Part must be clean, dry and at a temperature of 4.4-52°C (40- 125°F) before penetrant is applied.
  2. Apply penetrant using spray, immersion, or wipe on.
  3. Wait a minimum of 10 minutes; 20 minutes if temperature is 4.4-10°C (40-50°F).
  4. Moisten cloth with remover and wipe penetrant from surface. Do not spray remover on surface to remove penetrant, as sensitivity will be impaired.
  5. Apply nonaqueous developer D-70, by spraying.
  6. Wait a minimum of 10 minutes before inspection.
  7. For fluorescent Type 1 penetrants use UV-A illumination of >1000 µw/cm2 @ 15inches (38.1 cm) in a darkened area of <21 lux visible light (<2 footcandles). For visible Type 2 penetrants use lighting of 1100 lux/m2 (100 footcandles) minimum.

Physical Properties

  • Form: clear liquid
  • Density: 743 g/L (6.2 lb/gl)
  • Flash Point: >12.7°C (>55°F)
  • Fluorescence: none
  • Corrosion of aluminum: none
  • Corrosion of carbon steel: none
  • Corrosion of magnesium: none
  • Corrosion of stainless steel: none
  • Corrosion of titanium: none
  • Residue: < 0.005 g/100 ml
  • Chloride content: < 50 ppm (< 0.005%)
  • Fluoride content: < 50 ppm (< 0.005%)
  • Sulfur content: < 100 ppm (< 0.01%)
  • Mercury: none
  • VOC's: 743 g/L
  • Ozone layer depleting substances: none
  • PCB's: none

Specifications

  • AMS-2644E
  • AMS-2647C
  • ASME B & PV code 07 sec V
  • ASTM E-165
  • ASTM E-1417
  • ISO-3452-2005
  • NAVSEA-T9074-AS-GIB-010/271
  • RCC-M rev 2000
  • Frequently Purchased With
  • Customers Also Viewed

Reviews

Q&A

Please note, Aircraft Spruce Australia's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Aircraft Spruce Australia assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.

Q: Is there a shelf life on Met-L-Chek?

This product has a 5 year shelf life from batch approval.

View in Catalog

View Image View in Catalog