Senders, clamp type senders with 3/16" diameter probe. EGT Senders have 4 feet leads. (All Rotax) Note: Westberg 712 Series Thermocouples are for Non-TSO’d CHT & EGT Gauges only. They have two small pins which are the same size. Made in USA |
I will review it for you when it arrives
Westach EGT Probe K Wire 1-5/8-2.5 Clamp 712-32Dwk Non-TSO
Westach EGT Probe K Wire 1-5/8-2.5 Clamp 712-32Dwk Non-TSO
Please note, Aircraft Spruce Australia's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Aircraft Spruce Australia assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.
Yes, they will work together.
Part number 10-01257 has a 1-5/8" to 2" clamp with a 1/2" tip. Part number 10-01225 has the same clamp with a 1" tip. Part number 10-01233 has a 1-1/4" to 1-3/4" clamp with a 1/2" tip.
For the Rotax 912, you would need PN: 10-01844.
Yes, this probe is grounded. For type K ungrounded see part 10-25225.
Most Continental engines use 18MM gasket probes. Please confirm with your maintenance manual before purchase. See part number 10-01226 and 10-01225.
Westach no longer makes a certified replacement for this probe. I believe 712-2DWK will work but it does not have FAA approval.