Concorde recombinant gas (RGŪ Series) valve regulated lead acid (VRLA) batteries for engine starting, emergency / essential power, and standby power applications are constructed with cutting edge Absorbed Glass Mat (AGM) technology. Concorde VRLA-AGM batteries are well known for quality and their ability to perform reliably in hot & cold climates with superior engine starting performance and excellent charge acceptance.
|
Please note, Aircraft Spruce Australia's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Aircraft Spruce Australia assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.
This battery is not rated in cold cranking amps but instead in an IPP/IPR rating.
74 Degrees F | IPP = 1000 amps | IPR = 650 amps
0 Degrees F | IPP = 750 amps | IPR = 600 amps
-22 Degrees F | IPP = 550 amps | IPR = 450 amps
No, this is not considered dangerous goods for shipping purposes.